Cold-rolled steel systems for fire rated and bullet resistant glazing

Fire rated doors and partitions, fire rated curtain wall, and bullet resistant systems — three ranges built from one family of cold-rolled galvanised steel profiles, so a project carries one specification from the facade to the lift lobby.

Schematic section through a fire rated glazed unit. The exposed face is on the left and the protected face on the right; heat advances from left to right as the test runs.FIRE FACEPROTECTED FACEOUTER PANEINTERLAYERINNER PANESTEEL PROFILE, CAPTURED BOTH EDGESThe ISO 834 standard fire curve: 842 degrees Celsius at 30 minutes, 945 at 60 minutes and 1049 at 120 minutes.02004006008001000°C0306090120MINUTES

Elapsed

120 min

Furnace

1049 °C

ISO 834 standard curve. Observation logs from the test laboratories appear here once written approval to reproduce them is on file.

The ISO 834 standard fire curve, the temperature a test furnace is held to under BS 476-20 and IS 16945.

One wall, two sides

What a fire rated glazed wall actually is

Two panes of glass and an interlayer, held on both edges by a cold-rolled steel profile. On the fire side the temperature runs past a thousand degrees; the protected side stays intact and people can move behind it.

A fire rated glazed wall in section, fire on one side and the protected side on the other. The wall is built from an outer pane, an interlayer and an inner pane of glass, held on both edges by a cold-rolled steel profile. On the fire side the temperature reaches over a thousand degrees; the protected side stays intact. FIRE SIDE Over 1000°C in a test PROTECTED SIDE Stays intact Outer pane Interlayer Inner pane Steel profile Steel profile One wall. The fire is on one side; the people are on the other.
How a fire rated glazed wall is built: two panes and an interlayer, held on both edges by a steel profile.

Three system lines

Three systems, and what each one is for

A pair of glazed doors in a slim dark steel frame with push bars and overhead closers, set in a glazed screen that continues along a concrete lobby wall.

FT-PD

E120 EI30 EW120

Fire Rated Doors & Partitions

Steel framing for building entrances, lift lobbies, server rooms and corridors. A two-hour fire rating - 120 minutes integrity and 120 minutes radiation control - classified E120 / EI30 / EW120.

A multi-storey curtain wall facade in a slim dark steel grid seen at a raking angle from ground level, regular glazed bays running the full height of the elevation with an overcast sky reflected across them.

FT-CW

E120 EI30 EW120

Fire Rated Curtain Wall

Mullion and transom curtain wall on a slim 45-60 mm face. The curtain wall was intact on both faces at the end of a two-hour test.

The corner of a thick multi-ply laminated glass panel held in a dark steel frame, the exposed edge showing the stack of glass plies and interlayers.

BR-Shield

BR6 FB6

Bullet Resistant Systems

Cold-rolled steel systems with glass in the system, as door systems, fixed partitions and cap curtain wall. Tested to EN 1063 BR6 and EN 1522 FB6 - partial compliance.

The classifications above are what the test reports record. Where a marketing claim runs ahead of a report, this site prints the report.

NBC · Made in India

Built for the way Indian projects are specified

Public work in India is specified against the National Building Code. A facade system developed against it is a shorter route through a tender than one that was not.

The FT-PD and FT-CW systems are developed against the National Building Code, and made in India, in Mumbai. For a government specifier those facts do more work than any product feature.

They are set out below. Firetec makes its own cold-rolled steel, in India, and develops it to the codes Indian projects are specified against.

45–60mm

Curtain wall face width

60–200mm

Curtain wall profile depth

Compliance positions

Compliance positions
National Building CodeDeveloped against NBC normsFiretec
ManufactureMumbaiFiretec
Profile materialCold-rolled galvanised steelFiretec
Curtain wall face width45–60 mmFiretec
Curtain wall profile depth60–200 mmFiretec
Laboratory accreditationNABL, ILAC-MRA and ISO 9001:2015Test reports

Laboratories and standards

Tested, not claimed

Four laboratories have had these systems in a furnace or in front of a rifle. What follows states the standards and the outcomes. No report extract, certificate image or shot datum appears anywhere on this site.

The two fire tests were run at two different laboratories, and neither is named here at Firetec’s request. Both are NABL accredited and covered by ILAC. The two ballistic laboratories are named, because Firetec has cleared those.

FT-CW

NABL accredited laboratory

BS 476-20:1987 BS 476-22:1987

120min

Integrity · intact both faces

A fully glazed curtain wall in a 2400 × 3000 mm opening, held to the standard curve for two hours, with radiation below 15 kW/m² throughout.

Insulation was 42 minutes, which supports EI30.

FT-PD

NABL accredited laboratory

IS 16945:2018

120min

Integrity and radiation

A fire rated glazed partition in steel framing, held to the standard curve for two hours. Genuinely strong figures for glazed steel.

The range holds a two-hour fire rating and is classified E120 / EI30 / EW120.

BR-Shield

NFSU Gandhinagar

EN 1063 BR6 EN 1522 FB6

846–860m/s

Fired at, against a BR6 band of 820–840

The NFSU Ballistic Research Centre is ISO 9001:2015 certified. BR-Shield has been trialled there against 7.62 × 51 mm ammunition.

The report records the result as partial compliance with EN 1063 BR6 and EN 1522 FB6, so “tested to” is the accurate phrase and “certified” is not. It is a restricted document, so no figure from it is reproduced here.

BR-Shield

TBRL Chandigarh

EN 1063 BR6 EN 1522 FB6

Withheld · reproduction restricted

TBRL Chandigarh is a DRDO laboratory, and BR-Shield has been trialled there against the same ammunition. Its report records the same result: partial compliance.

It is also a restricted document, which is why no figure from it is reproduced here.

Full test reports are available to specifiers on request.

Request the reports

Six sectors

Where these systems get specified

Fire and security requirements differ by building type, and so does the argument you have to make to a consultant. These are the six sectors the systems go into most often.

A glazed partition wall in a slim dark steel frame running the length of a data hall, server racks and their indicator lights visible through it, cable tray overhead.

15kW/m²

The EW threshold, at one metre

Read the sector: Data centres
A curved glazed concourse wall in a slim dark frame, check-in desks along the far side and the apron visible through the glass.

60–200mm

Profile depth, for span

Read the sector: Airports and transit
A glazed partition corridor in dark steel framing inside a hospital, a linen trolley and a wheelchair against the far wall and a handrail running the length of it.

180min

FT-PD integrity, defend in place

Read the sector: Hospitals
A teller line: a stone counter with a glazed screen in a steel frame above it, customer seating on the near side and a lit desk with ledgers on the far side.

846–860m/s

Fired at NFSU, BR6 band 820–840

Read the sector: Banking and finance
A hotel lobby with a full-height steel-framed glazed screen dividing the seating area, timber panelling and a luggage trolley beyond it.

60mm

One face width, rated and unrated

Read the sector: Hospitality
An upper-floor lift lobby behind glazed partitions in a slim dark frame, lift doors to one side and the city visible through the facade.

3

System lines, one steel system

Read the sector: Commercial offices

Next step

Request the catalogue

Profile geometry, component schedules, door typologies and the BR threat table, for all three systems. Tell us what you are specifying and we will send the test reports relevant to it as well.